VSM 6 Bio-Parameters Monitoring

Non-invasive Pre Donation Hemoglobin Screening

Tailored for Blood Banks

Non-invasive Hemoglobin Test
Non-invasive
Eliminate risks of blood contamination
Save on
consumables
No more  biohazard waste
Accurate results in 60 seconds
testing heart rate while putting fingure of patient in device

6 Tests in ONE Device

  • Heart Rate

  • Oxygen Saturation

  • Blood Pressure

  • Hemoglobin

  • Hematocrit

  • Red Blood Cells

Manage Your Donors' Database

  • Share the results with your donors

  • Send reminders for future donations

  • Data integration using API

donors database graph

Medically Tested & Clinicly Proven.

CE, CFDA , Anvisa Approved
  • HOW DOES IT WORK
    Four LED lights shine wavelengths from visual light to infrared light through the fingertip As the light wave pass through the fingertip, some of it is absorbed and the light signal is changed Next, a camera sensor detects the changed light signal in real time Using patented algorithms and a vast amount of data the device analyzes the correlation between the signal and the bio parameters
  • UNIQUE TECHNOLOGY
    Continuous, Non-invasive and Cuff-free Blood Pressure Non-invasive Hemoglobin, Hematocrit, and RBC Non-invasive Blood Gases (Ph, PCO2, PO2, O2&CO2 Content) Non invasive Cardiac Output , Stroke Volume, MAP Bluetooth – Cloud Connectivity
  • PARTS INCLUDED
    TensorTip is supplied with the following components: Battery charger Input: 100v~-240v~, 50Hz – 60Hz DC Output: 5v / 1300mA Stand/Finger Chamber cover Protective pouch Self-Test Arc User Manual
  • INSTRUCTIONS FOR DISINFECTION
    1. Washing your hands: Before using the device, wash hands thoroughly with warm water to prevent contamination and infections. Dry hands completely with the use of a clean towel. 2. Disinfection of hands: Apply 70% alcohol hand sanitizer and wait for alcohol to air dry. 3. Disinfecting the device before measuring: I. Open the lid of the fingertip compartment. II. Clean the finger compartment well with a 70% Isopropyl alcohol wipe (make sure the pad is moist, not soaked, to prevent the alcohol from permeating the device). Do not to touch the gel component with alcohol, only the plastic part. III. Wait for the alcohol to air dry. iv. Close the finger compartment. 4. After the measurement: Wipe with 70% Isopropyl alcohol moist wipes (pads) the entire device (inside and out) to prevent infections. Do not to touch the gel component with alcohol, only the plastic part.
Brazillians showing victory sign in jungle
Monitoring Vast Population in Rural Areas

For The last 4 year the native population of the Amazonas river has been monitored by using Cnoga’s non-invasive VSM device for Hemoglobin levels and other bio-parameters. The medical data was stored by Cnoga’s ’Singular’ cloud data management system for future analysis and follow up. Due to periodic check-up of the bio-parameters(e.g. hemoglobin), the self-awareness of the monitored population has led to improvement of the daily nutrition that resulted in better wellbeing of the population

FAQ

  • HOW DOES IT WORK
    Four LED lights shine wavelengths from visual light to infrared light through the fingertip As the light wave pass through the fingertip, some of it is absorbed and the light signal is changed Next, a camera sensor detects the changed light signal in real time Using patented algorithms and a vast amount of data the device analyzes the correlation between the signal and the bio parameters
  • UNIQUE TECHNOLOGY
    Continuous, Non-invasive and Cuff-free Blood Pressure Non-invasive Hemoglobin, Hematocrit, and RBC Non-invasive Blood Gases (Ph, PCO2, PO2, O2&CO2 Content) Non invasive Cardiac Output , Stroke Volume, MAP Bluetooth – Cloud Connectivity
  • PARTS INCLUDED
    TensorTip is supplied with the following components: Battery charger Input: 100v~-240v~, 50Hz – 60Hz DC Output: 5v / 1300mA Stand/Finger Chamber cover Protective pouch Self-Test Arc User Manual
  • INSTRUCTIONS FOR DISINFECTION
    1. Washing your hands: Before using the device, wash hands thoroughly with warm water to prevent contamination and infections. Dry hands completely with the use of a clean towel. 2. Disinfection of hands: Apply 70% alcohol hand sanitizer and wait for alcohol to air dry. 3. Disinfecting the device before measuring: I. Open the lid of the fingertip compartment. II. Clean the finger compartment well with a 70% Isopropyl alcohol wipe (make sure the pad is moist, not soaked, to prevent the alcohol from permeating the device). Do not to touch the gel component with alcohol, only the plastic part. III. Wait for the alcohol to air dry. iv. Close the finger compartment. 4. After the measurement: Wipe with 70% Isopropyl alcohol moist wipes (pads) the entire device (inside and out) to prevent infections. Do not to touch the gel component with alcohol, only the plastic part.